Air & Gas diaphragm vacuum pumps, applications and advantages
ELECTRICAL DATA, BCHX2 8900 :
- Rated Voltage 230V 50Hz ou 120V 60Hz
- 2 models: in parallel or in series
- IP protection : IP00
- Insulation class : Class B
- Motor type : Shaded pole
STANDARD HEAD CONFIGURATION :
- Head Pump : PPS
- Diaphragm : FPM
- Valves : FPM
- O-Rings : SILICONE
Applications :
- Sampling
- Pressurization
Air & Gas diaphragm vacuum pumps, applications and advantages
ELECTRICAL DATA, BSHX18900 :
- Rated voltage 230V 50Hz or 120V 60Hz
- Have an integrated filter 400 μm
- IP protection : IP 00
- Insulation class : Therminal switch 120°C
- Motor type : Shaded pole
STANDARD HEAD CONFIGURATION
- Head Pump : PPS
- Diaphragm : FPM
- Valves : FPM
- O-Rings : SILICONE
Applications :
- Sampling
- Pressurization
Air & Gas diaphragm vacuum pumps, applications and advantages
ELECTRICAL DATA, BCHX2 6900 :
- Rated Voltage 12V dc or 24V dc
- 2 models: in parallel or in series
- IP protection : IP20
- Insulation class : Class E
- Motor type : Direct Current
STANDARD HEAD CONFIGURATION :
- Head Pump : PPS
- Diaphragm : FPM
- Valves : FPM
- O-Rings : SILICONE
Applications :
- Sampling
- Transfer
- Dosage
- Pressurization
Air & Gas diaphragm vacuum pumps, applications and advantages
ELECTRICAL DATA, BSHX16900 :
- Rated voltage 230V 50Hz or 120V 60Hz
- Have an integrated filter 400 μm
- IP protection : IP20
- Insulation class : Class E
- Motor type : Direct current
STANDARD HEAD CONFIGURATION :
- Head Pump : PPS
- Diaphragm : FPM
- Valves : FPM
- O-Rings : SILICONE
Applications :
- Sampling
- Transfer
Blowers and exhausters advantages
The air flow amplifier uses a small amount of compressed air to drive more, following the COANDA effect. .Applications
• Booster • Pneumatic operation • Vacuum conveying of powders and granularDosing Venturis, applications and advantages
Under the effect of the water pressure, the Venturi dispenser drives and dilutes one or two liquid products intended to clean hands or equipment contaminated by their use.Venturi dosing kits for disinfection and hygiene machines are delivered with non-return valve, EPDM O-ring, hose, strainer and set of nozzles.
.
Use of the venturi dispenser
• Dishwasher tunnels • Hand disinfection • Boot washerElectric Vacuum Switch, applications and advantages
The PSE100E series vacuum switch with electric output allows the vacuum level in the system to be checked by means of a patented system.
.
Advantages :
• It is adapted to all electrical automated systems • The choice between the N.O. or N.C. function is made during wiring.Electric Vacuum Switch, applications and advantages
The PSE 100 P series vacuum switch with pneumatic output allows the vacuum level in the system to be checked by means of a patented system.
.
This vacuum switch exists in two versions :
• NO version recommended for the «air saving» function on a venturi. • NC version for the « safety » function (object detected, ect.) and « SFC signal ».Electronic Infrared Detection Basin Mixer, applications and advantages.
Infrared detection basin tap are fitted to domestic hot water installations (sinks) and allow action on a desired temperature. Depending on the model, the faucet will be battery operated and will be equipped with an infrared sensor.- Chromed brass body
- Infra-red sensor
- Bi-stable solenoid valve with water connections G1/2” (external)
- Copper connecting pipe
- 4 alkaline batteries with water proof housing (external)
- Flow rate 6 l/min
- Operating pressure : Min 1 - max 8 bar
- Water inlet temperature : 5 - 70 °C
Electronic Infrared Detection Basin Mixer, applications and advantages.
Electronic mixing valves with fixed spouts are fitted to domestic hot water installations (sinks) and allow action on a desired temperature. Depending on the model, the faucet will be battery operated and will be equipped with an infrared sensor.- Chromed brass body
- Chromed brass fixed spout
- Bi-stable solenoid valve 6 V (internal)
- Infra-red sensor
- 6 V CRP2 lithium battery (internal)
- Stainless steel braided 1/2” flexible hoses and check valves
- Flow rate 6 l/min
- Operating pressure : Min 1 - max 8 bar
- Water inlet temperature : 5 - 70 °C
Electronic Infrared Detection Basin Mixer, applications and advantages.
Electronic Infrared Detection Basin Mixer are fitted to domestic hot water installations (sinks) and allow action on a desired temperature. Depending on the model, the faucet will be battery operated and will be equipped with an infrared sensor.Chromed zamak main body and cover- Bi-stable solenoid valve 6 V (internal)
- Infra-red sensor
- Hot water temperature lock system
- 6 V CRP2 lithium battery (internal)
- With check valves
- Stainless steel flexible hoses 1/2” with filters
- Flow rate 6 l/min
- Operating pressure : Min 1 - max 8 bar
- Water inlet temperature : 5 - 70 °C
The selection of the best industrial supplies to easily meet your industrial installation needs are available on www.best-supplies.com